Warning: mysql_free_result() expects parameter 1 to be resource, null given in /var/www/vhosts/vps.laumas.com/laumas.com/include/productGroupsSlug.php on line 84
Click on the desired product to access the relevant sheet in PDF format.
Manuals and product sheets with price list are only available to registered users.
 

ALL PRODUCTS - Weight transmitters

  LCB 

 
 
UNIVERSAL LOAD CELLS DIGITIZER
 
Clicca qui per i dettagli  

LCB Digitizer transforms an analog load cell (output mV/V) into digital and can also be used on existing load cells or strain gauge sensors. Designed for an assembly/wiring integral with the load cell body, it can be connected by fieldbus to PLCs of the most important international brands.

  • Optional fieldbuses: PROFINET IO, Ethernet/IP, Ethernet TCP/IP, Modbus TCP, PROFIBUS DP, EtherCAT, POWERLINK, CANopen, CC-Link, CC-Link IE, SERCOS III, IO-LINK.
  • Micro USB port
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V (optional)
  • RS485 port (optional)
  • Direct connection between RS485 and RS232 without converter.
  • 2 logic inputs, 3 relay outputs
  • Single loading batchings, max 99 formulas
   

  TLB4 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL-ANALOG WEIGHT TRANSMITTER ( RS485 )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 RS485 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER ( RS485 )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 CANOPEN 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - CANopen )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • CANopen port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 DEVICENET 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - DeviceNet )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).
 
  • DeviceNet port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 CC-LINK 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - CC-Link )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • CC-Link port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 PROFIBUS 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFIBUS )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • PROFIBUS DP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 PROFINET IO 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFINET IO)
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Two PROFINET IO ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 ETHERNET/IP 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet/IP )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Two Ethernet /IP ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 MODBUS/TCP 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - Modbus/TCP )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Back panel mounting on Omega/DIN rail
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 ETHERNET TCP/IP 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet TCP/IP )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 ETHERCAT 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - EtherCAT )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Two EtherCAT ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 POWERLINK 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 – POWERLINK )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • Two POWERLINK ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 SERCOS III 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - SERCOS III )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Two SERCOS III ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLKWF 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL
 
WiFi DIGITAL WEIGHT TRANSMITTER ( RS232 - RS485 )
 
Clicca qui per i dettagli  
  • Wifi module for wireless connection via integrated web server (for remote management to PC, smartphone, tablet, etc.) or via Modbus RTU/Laumas ASCII protocol.
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • Connectable to others TLKWF devices and W series Laumas instruments with OPZW1RADIO optional
  • 2 digital inputs, 4 relay digital outputs
  • 1 load cell input
  • Wall mounting
   

  TLK 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL
 
DIGITAL WEIGHT TRANSMITTER ( RS232 - RS485 )
 
Clicca qui per i dettagli  
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 4 relay digital outputs
  • 1 load cell input
  • Wall mounting
   

  MODWF 

 
EAC CERTIFICATION
 
WiFi / SERIAL TRANSCEIVER ( RS232 – RS485 )
 
Clicca qui per i dettagli  
WiFi communication interface device between two serial devices.

  • Wifi module for wireless connection via Modbus RTU, Laumas ASCII protocol
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • Connectable to others MODWF devices devices and W series Laumas instruments with OPZW1RADIO optional
  • Wall mounting
   

  TLB 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER ( RS485 )
 
Clicca qui per i dettagli  
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB 485 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER ( RS485 )
 
Clicca qui per i dettagli  
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB CANOPEN 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - CANopen )
 
Clicca qui per i dettagli  
  • CANopen port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB DEVICENET 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - DeviceNet )
 
Clicca qui per i dettagli  
  • DeviceNet port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB CC-LINK 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - CC-Link )
 
Clicca qui per i dettagli  
  • CC-Link port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB PROFI 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFIBUS )
 
Clicca qui per i dettagli  
  • PROFIBUS DP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB PROFINET IO 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFINET IO)
 
Clicca qui per i dettagli  
  • Two PROFINET IO ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB ETHERNET/IP 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet/IP )
 
Clicca qui per i dettagli  
  • Ethernet /IP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB MODBUS/TCP 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - Modbus/TCP )
 
Clicca qui per i dettagli  
  • Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB ETHERNET TCP/IP 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet TCP/IP )
 
Clicca qui per i dettagli  
  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB ETHERCAT 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - EtherCAT )
 
Clicca qui per i dettagli  
  • Two EtherCAT ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB POWERLINK 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 – POWERLINK )
 
Clicca qui per i dettagli  
  • Two POWERLINK ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB SERCOS III 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - SERCOS III )
 
Clicca qui per i dettagli  
  • Two SERCOS III ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  WEBLAU 

 
WEB SERVER MASTER FOR W AND TLB SERIES (max 8)
 
Clicca qui per i dettagli  
  • Ideal for supervision, management and remote control of the W series weight indicators and TLB series weight transmitters (max 8 instruments)
  • RS485 port (Modbus RTU)
  • Ethernet TCP/IP port for remote management via internet from PC, smartphone or tablet, etc.
  • Back panel mounting on Omega/DIN rail  

The WEBLAU device is a useful support for all installers/dealers of Laumas weighing instruments as it makes easier the remote maintenance, allowing to control wherever, the status of the instruments connected to RS485 including the possible anomalies.
   

  CLM8 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL
 
INTELLIGENT JUNCTION BOXES - 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The CLM8 series offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • OIML R76:2006 approved, class III, 3x5000 divis. 0.4μV/VSI

Available versions:

  • IP67 stainless steel box: 200x148x45 mm; 8+2 cable glands - plugs.
  • IP67 ABS box: 210x130x40 mm; 4/8+2 cable glands - plugs, 4/8+2 PVC end fittings.
  • IP67 polycarbonate box: 170x140x95 mm; 4/8+2 PG9 cable glands – plugs, 4/8+2 PVC end fittings.
  • Omega/DIN rail mounting version: 125x92x52 mm.
  • Board only: 151x72x30 mm.
   

  TLM8 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER ( RS485 ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 CANOPEN 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 – CANopen ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave CANopen port, max 99 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 DEVICENET 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 – DeviceNet ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave DeviceNet port, max 64 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 CC-LINK 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 - CC-Link ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave CC-Link port, max 64 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 PROFIBUS 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 – PROFIBUS ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave PROFIBUS DP port (max 32 instruments without line repeaters; max 126 instruments with line repeaters)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 PROFINET IO 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 - PROFINET IO ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Two PROFINET IO ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 ETHERNET/IP 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 - Ethernet/IP ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave Ethernet /IP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 MODBUS/TCP 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 - Modbus/TCP ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 ETHERCAT 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 – EtherCAT ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Two EtherCAT ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 ETHERNET TCP/IP 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 - Ethernet TCP/IP ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.
 
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 POWERLINK 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 – POWERLINK ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Two POWERLINK ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 SERCOS III 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 - SERCOS III ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Two SERCOS III ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLE 

ATEX CERTIFICATION“UL RECOGNIZED COMPONENT” CERTIFICATION
 
ANALOG WEIGHT TRANSMITTER ( RS485 )
 
Clicca qui per i dettagli  
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU)
  • Simple zero setting and full scale through digital rotary control (Encoder)
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
   

  TLS 485 

ATEX CERTIFICATIONEAC CERTIFICATION“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER ( RS485 )
 
Clicca qui per i dettagli  
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 2 optorelays logic outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
   

  TLS 

ATEX CERTIFICATIONEAC CERTIFICATION“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER ( RS485 )
 
Clicca qui per i dettagli  
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 2 optorelays logic outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
   

  THFPROFI 

EC-TYPE APPROVAL (NAWI - MID/AWI)ATEX CERTIFICATIONEAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER ( RS485 - PROFIBUS )
 
Clicca qui per i dettagli  
  • Slave Profibus DP port (max 32 instruments without line repeaters; max 126 instruments with line repeaters)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 1 logic input, 1 relay output
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
   

  TLU 

ATEX CERTIFICATIONEAC CERTIFICATION“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG LOAD LIMITING DEVICE/INDICATOR
 
Clicca qui per i dettagli  
  • Suitable for lifting systems
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V (optional)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 4 relay outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
   

  TLL 

ATEX CERTIFICATIONEAC CERTIFICATION“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER ( RS232 - RS485 )
 
Clicca qui per i dettagli  
  • Synchronous weight transmission for PLCs without serial port
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V (optional)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 4 relay outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
   

  CASTLATEX 

ATEX CERTIFICATION
 
IP67 CASE WITH TRANSPARENT COVER
 
Clicca qui per i dettagli  
For weight transmitter series TLE

  • ATEX II 3GD approved
  • Dimensions 170x140x95 mm; centre distance 122x152 mm
  • 6 PG9 cable glands
   

  CASTLTASTATEX 

ATEX CERTIFICATION
 
IP67 CASE WITH EXTERNAL KEYPAD
 
Clicca qui per i dettagli  
For weight transmitters: TLS, TLS485, TLU, TLL, THFPROFI

  • ATEX II 3GD approved
  • Dimensions 170x140x95 mm; centre distance 122x152 mm
  • 6 PG9 cable glands
   

  TPS - JOLLYTPS 

EAC CERTIFICATION
 
ANALOG WEIGHT TRANSMITTER
 
Clicca qui per i dettagli  
  • Analog output: 0/4-20 mA; 0-10V
  • Mounting on Omega/DIN rail for back panel or junction box
  • IP67 box version
   

  LCD2 

EAC CERTIFICATION
 
DIGITAL LOAD LIMITING DEVICE
 
Clicca qui per i dettagli  
  • Suitable for lifting systems
  • RS232 and RS485 ports
  • 1 logic input, 3 relay outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Limiting the load in dual safety redundant systems
  • Limiting the load in more-weighing systems
   

 
 

LOGIN CUSTOMER AREA

Enter the reserved area:




Forgotten your password?



Browse online catalogs
Download - Search a manual?
Sales Network Technical support Information about shipments
     
Top