INNOVATION IN WEIGHING

Weight transmitters

Show search filters

LOAD CELL AMPLIFIERS

LAUMAS load cell converters feature all the most common fieldbuses for communication with all PLCs on the market. Single- and multi-channel weight transmitters are available with integrated diagnostics for the connected load cells. They are also versatile in size, offering compact, space-saving, and cost-effective solutions.

Scroll through the items or use the filters to select the most suitable one.

Found 35 products
TLC - ANALOG WEIGHT TRANSMITTER
ANALOG WEIGHT TRANSMITTER
Current or voltage analog output.
1 load cell dedicated input.
Compatibile with analog/digital boards normally installed on PLC.
Calibration with sample weights or load cell simulator.
Ideal for use with tension/compression load cells.

Connections to:
  • PLC via analog output
  • up to 4 load cells in parallel by junction box
TLB4 - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485)
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 RS485 - DIGITAL WEIGHT TRANSMITTER (RS485)
DIGITAL WEIGHT TRANSMITTER (RS485)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 CANOPEN - DIGITAL WEIGHT TRANSMITTER (RS485 -  CANopen)
DIGITAL WEIGHT TRANSMITTER (RS485 - CANopen)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • CANopen port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 DEVICENET - DIGITAL WEIGHT TRANSMITTER (RS485 -  DeviceNet)
DIGITAL WEIGHT TRANSMITTER (RS485 - DeviceNet)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.
 
  • DeviceNet port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 CC-LINK - DIGITAL WEIGHT TRANSMITTER (RS485 - CC-Link)
DIGITAL WEIGHT TRANSMITTER (RS485 - CC-Link)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • CC-Link port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 PROFIBUS - DIGITAL WEIGHT TRANSMITTER (RS485 -  PROFIBUS)
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFIBUS)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • PROFIBUS DP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel
TLB4 PROFINET IO - DIGITAL WEIGHT TRANSMITTER (RS485 - PROFINET IO)
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFINET IO)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Two PROFINET IO ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 ETHERNET/IP - DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet/IP)
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet/IP)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Two Ethernet /IP ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 MODBUS/TCP - DIGITAL WEIGHT TRANSMITTER (RS485 - Modbus/TCP)
DIGITAL WEIGHT TRANSMITTER (RS485 - Modbus/TCP)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Back panel mounting on Omega/DIN rail
  • Mounting on Omega/DIN rail for front/back panel
TLB4 ETHERNET TCP/IP - DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet TCP/IP)
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet TCP/IP)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 ETHERCAT - DIGITAL WEIGHT TRANSMITTER (RS485 -  EtherCAT)
DIGITAL WEIGHT TRANSMITTER (RS485 - EtherCAT)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Two EtherCAT ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 POWERLINK - DIGITAL WEIGHT TRANSMITTER (RS485 – POWERLINK)
DIGITAL WEIGHT TRANSMITTER (RS485 – POWERLINK)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Two POWERLINK ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
TLB4 SERCOS III - DIGITAL WEIGHT TRANSMITTER (RS485 - SERCOS III)
DIGITAL WEIGHT TRANSMITTER (RS485 - SERCOS III)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Two SERCOS III ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
LCB - UNIVERSAL LOAD CELLS DIGITIZER
UNIVERSAL LOAD CELLS DIGITIZER

IP67 junction box made of AISI 304 stainless steel or PA66 nylon reinforced with glass fiber.

3 M12 IP67 connectors.
Dimensions: 90x40x107 mm including connectors.
6 LEDs for communication interface indication.

  • Optional fieldbuses: PROFINET IO, Ethernet/IP, Ethernet TCP/IP, Modbus TCP, PROFIBUS DP, EtherCAT, POWERLINK, CANopen, CC-Link, CC-Link IE Field Basic, SERCOS III, IO-LINK.
  • Micro USB port
  • 16-bit analog output: 0/4-20 mA; 0-5/10 V (optional)
  • RS485 port (optional)
  • Direct connection between RS485 and RS232 without converter
  • 2 logic inputs, 3 relay outputs
  • Single loading batchings, max 99 formulas
  • Mounting: wired or integral to the load cell body via standard ¼ GAS fitting
  • Suitable for wall mounting

The weight calculation rate reaches up to 500 values ​​per second, and the data update rate on the fieldbus can also reach a maximum speed of 500 updates per second when using PROFINET, EtherNet/IP, and EtherCAT buses.

TLKWF - WiFi DIGITAL WEIGHT TRANSMITTER (RS232 - RS485)
WiFi DIGITAL WEIGHT TRANSMITTER (RS232 - RS485)
  • Wifi module for wireless connection via integrated web server (for remote management to PC, smartphone, tablet, etc.) or via Modbus RTU/Laumas ASCII protocol.
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • Connectable to others TLKWF devices and W series Laumas instruments with OPZW1RADIO optional
  • 2 digital inputs, 4 relay digital outputs
  • 1 load cell input
  • Wall mounting
TLK - DIGITAL WEIGHT TRANSMITTER (RS232 - RS485)
DIGITAL WEIGHT TRANSMITTER (RS232 - RS485)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 4 relay digital outputs
  • 1 load cell input
  • Wall mounting
CLM8 - CLM16 - INTELLIGENT JUNCTION BOX - 8/16 CHANNELS FOR LOAD CELLS
INTELLIGENT JUNCTION BOX - 8/16 CHANNELS FOR LOAD CELLS
The CLM8 series offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells (16 channels by connecting 2 CLM8).
Digital equalization. Automatic diagnostics. Inclinometer function.

  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • OIML R 76:2006 approved, class III, 3x5000 divis. 0.4μV/VSI

Available versions:

  • IP67 stainless steel box: 200x148x45 mm; 8+2 cable glands - plugs.
  • IP67 polycarbonate box: 170x140x95 mm; 4/8+2 cable glands – plugs, 4+2 PVC end fittings.
  • Omega/DIN rail mounting version: 125x92x52 mm.
  • Board only: 151x72x30 mm.
TLM8 - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485) 8 CHANNELS FOR LOAD CELLS
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics. Inclinometer function.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 CANOPEN - DIGITAL WEIGHT TRANSMITTER (RS485, CANopen) 8 CHANNELS FOR LOAD CELLS
DIGITAL WEIGHT TRANSMITTER (RS485, CANopen) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics. Inclinometer function.

  • Slave CANopen port, max 99 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 DEVICENET - ANALOG WEIGHT TRANSMITTER (RS485, DeviceNet) 8 CHANNELS FOR LOAD CELLS
ANALOG WEIGHT TRANSMITTER (RS485, DeviceNet) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics. Inclinometer function.

  • Slave DeviceNet port, max 64 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 CC-LINK - DIGITAL WEIGHT TRANSMITTER (RS485, CC-Link) 8 CHANNELS FOR LOAD CELLS
DIGITAL WEIGHT TRANSMITTER (RS485, CC-Link) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics. Inclinometer function.

  • Slave CC-Link port, max 64 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 PROFIBUS - DIGITAL WEIGHT TRANSMITTER (RS485, PROFIBUS) 8 CHANNELS FOR LOAD CELLS
DIGITAL WEIGHT TRANSMITTER (RS485, PROFIBUS) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics. Inclinometer function.

  • Slave PROFIBUS DP port (max 32 instruments without line repeaters; max 126 instruments with line repeaters)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 PROFINET IO - DIGITAL WEIGHT TRANSMITTER (RS485, PROFINET IO) 8 CHANNELS FOR LOAD CELLS
DIGITAL WEIGHT TRANSMITTER (RS485, PROFINET IO) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics. Inclinometer function.

  • Two PROFINET IO ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 ETHERNET/IP - DIGITAL WEIGHT TRANSMITTER (RS485, Ethernet/IP) 8 CHANNELS FOR LOAD CELLS
DIGITAL WEIGHT TRANSMITTER (RS485, Ethernet/IP) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics. Inclinometer function.

  • Slave Ethernet /IP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 MODBUS/TCP - DIGITAL WEIGHT TRANSMITTER (RS485, Modbus/TCP) 8 CHANNELS FOR LOAD CELLS
DIGITAL WEIGHT TRANSMITTER (RS485, Modbus/TCP) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics. Inclinometer function.

  • Slave Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 ETHERCAT - DIGITAL WEIGHT TRANSMITTER (RS485, EtherCAT) 8 CHANNELS FOR LOAD CELLS
DIGITAL WEIGHT TRANSMITTER (RS485, EtherCAT) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics. Inclinometer function.

  • Two EtherCAT ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 ETHERNET TCP/IP - DIGITAL WEIGHT TRANSMITTER (RS485, Ethernet TCP/IP) 8 CHANNELS FOR LOAD CELLS
DIGITAL WEIGHT TRANSMITTER (RS485, Ethernet TCP/IP) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics. Inclinometer function.
 
  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 POWERLINK - DIGITAL WEIGHT TRANSMITTER (RS485, POWERLINK) 8 CHANNELS FOR LOAD CELLS
DIGITAL WEIGHT TRANSMITTER (RS485, POWERLINK) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics. Inclinometer function.


  • Two POWERLINK ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
TLM8 SERCOS III - DIGITAL WEIGHT TRANSMITTER (RS485, SERCOS III) 8 CHANNELS FOR LOAD CELLS
DIGITAL WEIGHT TRANSMITTER (RS485, SERCOS III) 8 CHANNELS FOR LOAD CELLS
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics. Inclinometer function.

  • Two SERCOS III ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
  • Hygienic version RPSCQC authorized by 3-A SSI
CASTLM8I - KASTEN AUS EDELSTAHL FÜR WÄGETRANSMITTER TLM8
KASTEN AUS EDELSTAHL FÜR WÄGETRANSMITTER TLM8
Für mehrkanaligen Wägetransmitter TLM8.

  • Schutzart IP68 (auf Anfrage IP69K)
  • Einbau an: Schalttafelfront, Wand, Tisch
  • Version ATEX II 3GD
  • TEST-Taste für den direkten Zugriff auf Diagnosefunktionen
CASTLM8I 3A - HYGIENIC STAINLESS STEEL BOX FOR TLM8 TRANSMITTER
HYGIENIC STAINLESS STEEL BOX FOR TLM8 TRANSMITTER

For multichannel weight transmitter series TLM8.

  • Hygienic device RPSCQC authorized by 3-A SSI
  • IP69K protection rating
  • Panel mounting
  • TEST key for direct access to the diagnostic functions
TLU - DIGITAL-ANALOG LOAD LIMITING DEVICE/WEIGHT TRANSMITTER
DIGITAL-ANALOG LOAD LIMITING DEVICE/WEIGHT TRANSMITTER
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V (optional)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 4 relay outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
LCD3 - DIGITAL LOAD LIMITING DEVICE
DIGITAL LOAD LIMITING DEVICE
  • Suitable for lifting systems
  • Single/multi-weighing system: load limitation (single and sum) for systems with up to 4 weighing points, by connecting multiple units.
  • 3 relay outputs
  • 1 load cell dedicated input
  • Load cells connections continuous check
  • Mounting on Omega/DIN rail for back panel or junction box
  • RS232 and RS485 ports
  • 2 digital inputs
  • Power Supply 24-48 Vdc/Vac
LCD3PL - DIGITAL LOAD LIMITING DEVICE
DIGITAL LOAD LIMITING DEVICE
  • Suitable for lifting systems
  • Dual channel input system for single or double bridge load cells, in accordance with category 2 as per EN 13849-1:2008, PL d (corresponding to SIL 2, EN62061 standard).
  • 4 relay outputs
  • 2 independent load cell inputs
  • Load cells connections continuous check
  • Mounting on Omega/DIN rail for back panel or junction box
  • RS232 and RS485 ports
  • 2 digital inputs
  • Power Supply 24-48 Vdc/Vac