WEIGHING INDICATORS
LAUMAS load cell indicators, beyond simply displaying weight, can be specifically designed for batching systems or weighbridges. A variety of display and installation options are available; they include analog and serial outputs as well as fieldbuses for PC/PLC connection; also suitable for harsh environments thanks to stainless steel models with protection ratings up to IP69K and for EX-classified areas.
Scroll through the items or use the filters to select the most suitable one.
WEIGHT INDICATOR (for weighing and batching)
- Panel mounting.
- White LED display with signalling symbols.
- Fieldbus: PROFINET IO.
- RS485 port (Modbus RTU/Laumas ASCII protocol).
- 2 digital inputs, 3 relay outputs.
- Bluetooth module for communication with Instrument Manager 2.0 configuration app.
- Data exchange via IoT protocols (OPC UA and MQTT).
- OIML R 76:2006 approved, class III, 3x10,000 divisions, 0.2μV/VSI
- Cybersecurity: secure by design.
- Single-product batching: base and LOADING programs - 99 settable formulas.
- Conversion rate: 1200 readings per second.
- Fieldbus update rate: 1000 Hz.
- Digital filter: 14 levels.
- Usable load cells sensitivity: ±7 mV/V÷±120 mV/V
- Alibi memory.
WEIGHT INDICATOR (for weighing and batching)
- Panel mounting.
- White LED display with signalling symbols.
- Fieldbus: EtherNet/IP.
- RS485 port (Modbus RTU/Laumas ASCII protocol).
- 2 digital inputs, 3 relay outputs.
- Bluetooth module for communication with Instrument Manager 2.0 configuration app.
- Data exchange via IoT protocols (OPC UA and MQTT).
- OIML R 76:2006 approved, class III, 3x10,000 divisions, 0.2μV/VSI
- Cybersecurity: secure by design.
- Single-product batching: base and LOADING programs - 99 settable formulas.
- Conversion rate: 1200 readings per second.
- Fieldbus update rate: 1000 Hz.
- Digital filter: 14 levels.
- Usable load cells sensitivity: ±7 mV/V÷±120 mV/V
- Alibi memory.
WEIGHT INDICATOR (for weighing and batching)
- Panel mounting.
- White LED display with signalling symbols.
- Fieldbus: EtherCAT.
- RS485 port (Modbus RTU/Laumas ASCII protocol).
- 2 digital inputs, 3 relay outputs.
- Bluetooth module for communication with Instrument Manager 2.0 configuration app.
- Data exchange via IoT protocols (OPC UA and MQTT).
- OIML R 76:2006 approved, class III, 3x10,000 divisions, 0.2μV/VSI
- Cybersecurity: secure by design.
- Single-product batching: base and LOADING programs - 99 settable formulas.
- Conversion rate: 1200 readings per second.
- Fieldbus update rate: 1000 Hz.
- Digital filter: 14 levels.
- Usable load cells sensitivity: ±7 mV/V÷±120 mV/V
- Alibi memory.