Os transmissores de pesagem LAUMAS dispõem de todos os principais buses de campo para comunicação com todos os PLC disponíveis no mercado. Estão disponíveis transmissores de peso monocanal e multicanal com diagnóstico integrado das células de carga conectadas. São também versáteis em termos de dimensão, com soluções compactas, que economizam espaço e são vantajosas.

Percorra os artigos ou use os filtros para encontrar o mais adequado.

TLB4 - DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485)
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.
  • Mounting on Omega/DIN rail for front/back panel
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • OIML R61, R51 approved - WELMEC Guide 8.8:2017 (MID) 
TLB4 RS485 - DIGITAL WEIGHT TRANSMITTER (RS485)
DIGITAL WEIGHT TRANSMITTER (RS485)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Mounting on Omega/DIN rail for front/back panel
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • OIML R61, R51 approved - WELMEC Guide 8.8:2017 (MID)
TLB4 CANOPEN - DIGITAL WEIGHT TRANSMITTER (RS485 -  CANopen)
DIGITAL WEIGHT TRANSMITTER (RS485 - CANopen)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Mounting on Omega/DIN rail for front/back panel
  • CANopen port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • OIML R61, R51 approved - WELMEC Guide 8.8:2017 (MID)
TLB4 DEVICENET - DIGITAL WEIGHT TRANSMITTER (RS485 -  DeviceNet)
DIGITAL WEIGHT TRANSMITTER (RS485 - DeviceNet)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.
 
  • Mounting on Omega/DIN rail for front/back panel
  • DeviceNet port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • OIML R61, R51 approved - WELMEC Guide 8.8:2017 (MID)
TLB4 CC-LINK - DIGITAL WEIGHT TRANSMITTER (RS485 - CC-Link)
DIGITAL WEIGHT TRANSMITTER (RS485 - CC-Link)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Mounting on Omega/DIN rail for front/back panel
  • CC-Link port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • OIML R61, R51 approved - WELMEC Guide 8.8:2017 (MID)
TLB4 PROFIBUS - DIGITAL WEIGHT TRANSMITTER (RS485 -  PROFIBUS)
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFIBUS)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Mounting on Omega/DIN rail for back panel
  • PROFIBUS DP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • OIML R61, R51 approved - WELMEC Guide 8.8:2017 (MID)
TLB4 PROFINET IO - DIGITAL WEIGHT TRANSMITTER (RS485 - PROFINET IO)
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFINET IO)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Mounting on Omega/DIN rail for front/back panel
  • PROFINET IO ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • OIML R61, R51 approved - WELMEC Guide 8.8:2017 (MID)
TLB4 ETHERNET/IP - DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet/IP)
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet/IP)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Mounting on Omega/DIN rail for front/back panel
  • 2 EtherNet /IP ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • OIML R61, R51 approved - WELMEC Guide 8.8:2017 (MID)
TLB4 MODBUS/TCP - DIGITAL WEIGHT TRANSMITTER (RS485 - Modbus/TCP)
DIGITAL WEIGHT TRANSMITTER (RS485 - Modbus/TCP)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Mounting on Omega/DIN rail for front/back panel
  • Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • OIML R61, R51 approved - WELMEC Guide 8.8:2017 (MID)
TLB4 ETHERNET TCP/IP - DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet TCP/IP)
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet TCP/IP)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Mounting on Omega/DIN rail for front/back panel
  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • OIML R61, R51 approved - WELMEC Guide 8.8:2017 (MID)
TLB4 ETHERCAT - DIGITAL WEIGHT TRANSMITTER (RS485 -  EtherCAT)
DIGITAL WEIGHT TRANSMITTER (RS485 - EtherCAT)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Mounting on Omega/DIN rail for front/back panel
  • EtherCAT ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • OIML R61, R51 approved - WELMEC Guide 8.8:2017 (MID)
TLB4 POWERLINK - DIGITAL WEIGHT TRANSMITTER (RS485 – POWERLINK)
DIGITAL WEIGHT TRANSMITTER (RS485 – POWERLINK)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Mounting on Omega/DIN rail for front/back panel
  • POWERLINK ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • OIML R61, R51 approved - WELMEC Guide 8.8:2017 (MID) 
TLB4 SERCOS III - DIGITAL WEIGHT TRANSMITTER (RS485 - SERCOS III)
DIGITAL WEIGHT TRANSMITTER (RS485 - SERCOS III)
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization). Inclinometer function.

  • Mounting on Omega/DIN rail for front/back panel
  • 2 SERCOS III ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI
  • OIML R61, R51 approved - WELMEC Guide 8.8:2017 (MID)
TLB 485 - DIGITAL WEIGHT TRANSMITTER (RS485)
DIGITAL WEIGHT TRANSMITTER (RS485)
  • Back panel mounting on Omega/DIN rail
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 3 relay outputs
  • OIML R 76:2006 approved, class III, 10,000 divis. 0.2μV/VSI