  TLB4 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL-ANALOG WEIGHT TRANSMITTER ( RS485 )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 RS485 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER ( RS485 )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 CANOPEN 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - CANopen )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • CANopen port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 DEVICENET 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - DeviceNet )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).
 
  • DeviceNet port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 CC-LINK 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - CC-Link )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • CC-Link port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 PROFIBUS 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFIBUS )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • PROFIBUS DP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 PROFINET IO 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFINET IO)
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Two PROFINET IO ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 ETHERNET/IP 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet/IP )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Two Ethernet /IP ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 MODBUS/TCP 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - Modbus/TCP )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Back panel mounting on Omega/DIN rail
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 ETHERNET TCP/IP 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet TCP/IP )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 ETHERCAT 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - EtherCAT )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Two EtherCAT ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 POWERLINK 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 – POWERLINK )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • Two POWERLINK ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLB4 SERCOS III 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATIONNMI CERTIFICATION for Australia
 
DIGITAL WEIGHT TRANSMITTER (RS485 - SERCOS III )
 
Clicca qui per i dettagli  
4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).  

  • Two SERCOS III ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
   

  TLKWF 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL
 
WiFi DIGITAL WEIGHT TRANSMITTER ( RS232 - RS485 )
 
Clicca qui per i dettagli  
  • Wifi module for wireless connection via integrated web server (for remote management to PC, smartphone, tablet, etc.) or via Modbus RTU/Laumas ASCII protocol.
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • Connectable to others TLKWF devices and W series Laumas instruments with OPZW1RADIO optional
  • 2 digital inputs, 4 relay digital outputs
  • 1 load cell input
  • Wall mounting
   

  TLK 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL
 
DIGITAL WEIGHT TRANSMITTER ( RS232 - RS485 )
 
Clicca qui per i dettagli  
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 4 relay digital outputs
  • 1 load cell input
  • Wall mounting
   

  MODWF 

 
EAC CERTIFICATION
 
WiFi / SERIAL TRANSCEIVER ( RS232 – RS485 )
 
Clicca qui per i dettagli  
WiFi communication interface device between two serial devices.

  • Wifi module for wireless connection via Modbus RTU, Laumas ASCII protocol
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • Connectable to others MODWF devices devices and W series Laumas instruments with OPZW1RADIO optional
  • Wall mounting
   

  TLB 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER ( RS485 )
 
Clicca qui per i dettagli  
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB 485 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER ( RS485 )
 
Clicca qui per i dettagli  
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB CANOPEN 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - CANopen )
 
Clicca qui per i dettagli  
  • CANopen port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB DEVICENET 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - DeviceNet )
 
Clicca qui per i dettagli  
  • DeviceNet port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB CC-LINK 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - CC-Link )
 
Clicca qui per i dettagli  
  • CC-Link port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB PROFI 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFIBUS )
 
Clicca qui per i dettagli  
  • PROFIBUS DP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB PROFINET IO 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - PROFINET IO)
 
Clicca qui per i dettagli  
  • PROFINET IO port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB ETHERNET/IP 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet/IP )
 
Clicca qui per i dettagli  
  • Ethernet /IP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB MODBUS/TCP 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - Modbus/TCP )
 
Clicca qui per i dettagli  
  • Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB ETHERNET TCP/IP 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - Ethernet TCP/IP )
 
Clicca qui per i dettagli  
  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB ETHERCAT 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - EtherCAT )
 
Clicca qui per i dettagli  
  • EtherCAT port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB POWERLINK 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 – POWERLINK )
 
Clicca qui per i dettagli  
  • POWERLINK port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  TLB SERCOS III 

EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONNTEP CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER (RS485 - SERCOS III )
 
Clicca qui per i dettagli  
  • SERCOS III port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
   

  WEBLAU 

 
WEB SERVER MASTER FOR W AND TLB SERIES (max 8)
 
Clicca qui per i dettagli  
  • Ideal for supervision, management and remote control of the W series weight indicators and TLB series weight transmitters (max 8 instruments)
  • RS485 port (Modbus RTU)
  • Ethernet TCP/IP port for remote management via internet from PC, smartphone or tablet, etc.
  • Back panel mounting on Omega/DIN rail  

The WEBLAU device is a useful support for all installers/dealers of Laumas weighing instruments as it makes easier the remote maintenance, allowing to control wherever, the status of the instruments connected to RS485 including the possible anomalies.
   

  CLM8 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL
 
INTELLIGENT JUNCTION BOXES - 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The CLM8 series offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • OIML R76:2006 approved, class III, 3x5000 divis. 0.4μV/VSI

Available versions:

  • IP67 stainless steel box: 200x148x45 mm; 8+2 cable glands - plugs.
  • IP67 ABS box: 210x130x40 mm; 4/8+2 cable glands - plugs, 4/8+2 PVC end fittings.
  • IP67 polycarbonate box: 170x140x95 mm; 4/8+2 PG9 cable glands – plugs, 4/8+2 PVC end fittings.
  • Omega/DIN rail mounting version: 125x92x52 mm.
  • Board only: 151x72x30 mm.
   

  TLM8 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER ( RS485 ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 CANOPEN 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 – CANopen ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave CANopen port, max 99 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 DEVICENET 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 – DeviceNet ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave DeviceNet port, max 64 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 CC-LINK 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 - CC-Link ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave CC-Link port, max 64 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 PROFIBUS 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 – PROFIBUS ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave PROFIBUS DP port (max 32 instruments without line repeaters; max 126 instruments with line repeaters)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 PROFINET IO 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 - PROFINET IO ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave PROFINET IO port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 ETHERNET/IP 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 - Ethernet/IP ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave Ethernet /IP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 MODBUS/TCP 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 - Modbus/TCP ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 ETHERCAT 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 – EtherCAT ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave EtherCAT port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 ETHERNET TCP/IP 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 - Ethernet TCP/IP ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.
 
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 POWERLINK 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 – POWERLINK ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave POWERLINK port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLM8 SERCOS III 

 
EC-TYPE APPROVAL (NAWI - MID/AWI)EAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485 - SERCOS III ) 8 CHANNELS FOR LOAD CELLS
 
Clicca qui per i dettagli  
The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.  

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave SERCOS III port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
   

  TLE 

ATEX CERTIFICATION“UL RECOGNIZED COMPONENT” CERTIFICATION
 
ANALOG WEIGHT TRANSMITTER ( RS485 )
 
Clicca qui per i dettagli  
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU)
  • Simple zero setting and full scale through digital rotary control (Encoder)
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
   

  TLS 485 

ATEX CERTIFICATIONEAC CERTIFICATION“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER ( RS485 )
 
Clicca qui per i dettagli  
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 2 optorelays logic outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
   

  TLS 

ATEX CERTIFICATIONEAC CERTIFICATION“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG WEIGHT TRANSMITTER ( RS485 )
 
Clicca qui per i dettagli  
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 2 optorelays logic outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
   

  THFPROFI 

EC-TYPE APPROVAL (NAWI - MID/AWI)ATEX CERTIFICATIONEAC CERTIFICATIONOIML APPROVAL“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER ( RS485 - PROFIBUS )
 
Clicca qui per i dettagli  
  • Slave Profibus DP port (max 32 instruments without line repeaters; max 126 instruments with line repeaters)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 1 logic input, 1 relay output
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 - WELMEC Guide 8.8:2011 (M.I.D.)
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
   

  TLU 

ATEX CERTIFICATIONEAC CERTIFICATION“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL-ANALOG LOAD LIMITING DEVICE/INDICATOR
 
Clicca qui per i dettagli  
  • Suitable for lifting systems
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V (optional)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 4 relay outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
   

  TLL 

ATEX CERTIFICATIONEAC CERTIFICATION“UL RECOGNIZED COMPONENT” CERTIFICATION
 
DIGITAL WEIGHT TRANSMITTER ( RS232 - RS485 )
 
Clicca qui per i dettagli  
  • Synchronous weight transmission for PLCs without serial port
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V (optional)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 4 relay outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
   

  CASTLATEX 

ATEX CERTIFICATION
 
IP67 CASE WITH TRANSPARENT COVER
 
Clicca qui per i dettagli  
For weight transmitter series TLE

  • ATEX II 3GD approved
  • Dimensions 170x140x95 mm; centre distance 122x152 mm
  • 6 PG9 cable glands
   

  CASTLTASTATEX 

ATEX CERTIFICATION
 
IP67 CASE WITH EXTERNAL KEYPAD
 
Clicca qui per i dettagli  
For weight transmitters: TLS, TLS485, TLU, TLL, THFPROFI

  • ATEX II 3GD approved
  • Dimensions 170x140x95 mm; centre distance 122x152 mm
  • 6 PG9 cable glands
   

  TPS - JOLLYTPS 

EAC CERTIFICATION
 
ANALOG WEIGHT TRANSMITTER
 
Clicca qui per i dettagli  
  • Analog output: 0/4-20 mA; 0-10V
  • Mounting on Omega/DIN rail for back panel or junction box
  • IP67 box version
   

  LCD2 

EAC CERTIFICATION
 
DIGITAL LOAD LIMITING DEVICE
 
Clicca qui per i dettagli  
  • Suitable for lifting systems
  • RS232 and RS485 ports
  • 1 logic input, 3 relay outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Limiting the load in dual safety redundant systems