/body>

 

 

 

Click on to view technical information and prices.

Request via email / fax your DISCOUNT rate.

All the information are available in PDF format. If you do not have Acrobat Reader program, download it now: Download Acrobat Reader

 
LOAD CELLS                      
           
  OFF-CENTER load cells series AS                      

  ATEX           

  Download data sheet

  Kg   0.25 - 0.5 - 1  ( for platforms 200 x 200 mm )

Click on the picture to enlarge

  - Alloy aluminum construction

  - Combined error < +/- 0.03%       

  - Sensitivity 1 - 2 mV/V +/-15%

  - Protection class IP 65   

                     
  OFF-CENTER load cells series AL        

  ATEX           

  Download data sheet  

  Kg   3 - 15 - 30 ( for platforms 300 x 300 mm )  

Click on the picture to enlarge

  - Alloy aluminum construction

  - Combined error < +/- 0.03%       

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 65   

                     
  OFF-CENTER load cells series ALL       

  OIML R60       ATEX           

  Download data sheet  

  Kg   3 - 10 -15 - 30 - 50 ( for platforms 250 x 300 mm )  

Click on the picture to enlarge

  - Alloy aluminum construction

  - Combined error < +/- 0.02%       

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 65   

                     
  OFF-CENTER load cells series AU      

  ATEX           

  Download data sheet

  Kg   3 - 6 - 15 ( for platforms 250 x 400 mm )  
  Kg   30 - 50 ( for platforms 400 x 600 mm )  

Clicca sulla foto per ingrandirla

  - Alloy aluminum construction

  - Combined error < +/- 0.02%       

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 65   

                     
  OFF-CENTER load cells series AF      

  ATEX           

  Download data sheet  

  Kg   5 - 15 ( for platforms 150 x 150 mm )  

Click on the picture to enlarge

  - Special steel construction

  - Combined error < +/- 0.05%       

  - Sensitivity 3 mV/V +/-5%

  - Protection class IP 65   

                     
  OFF-CENTER load cells series PR                               

  OIML R60        ATEX             

  Download data sheet  

  Kg   6 - 15 - 30 - 50 ( for platforms 350 x 350 mm )

Click on the picture to enlarge

  - Special steel construction

  - Combined error < +/- 0.025%       

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 67 

                     
  OFF-CENTER load cells series PRC                                

  ATEX             

  Download data sheet  

  Kg   6 - 15 - 30 - 50 ( for platforms 350 x 350 mm )

Click on the picture to enlarge

  - Stainless steel construction

  - Combined error < +/- 0.02%       

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 67 

                     
  OFF-CENTER load cells serie AZ        

  ATEX           

  Download data sheet  

  Kg   10 - 30 - 50 - 100 ( for platforms 400 x 400 mm )  

Click on the picture to enlarge

  - Alloy aluminum construction

  - Combined error < +/- 0.03%       

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 65   

                     
  OFF-CENTER load cells serie AZL         

  OIML R60       ATEX           

  Download data sheet  

  Kg   10 - 15 - 30 - 50 - 100 ( for platforms 400 x 400 mm )  

Click on the picture to enlarge

  - Alloy aluminum construction

  - Combined error < +/- 0.02%       

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 65   

                     
  OFF-CENTER load cells series PT                             

  OIML R60       ATEX         

  Download data sheet

  Kg   50 - 75 - 100 - 150 ( for platforms 400 x 400 mm )

Click on the picture to enlarge

  - Special steel construction

  - Combined error < +/- 0.02%     

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 67 

                     
  OFF-CENTER load cells series PTAI                             

  OIML R60       ATEX         

  Download data sheet

  Kg   30 - 50 - 100 - 200 ( for platforms 400 x 400 mm )

Click on the picture to enlarge

  - Stainless steel construction

  - Combined error < +/- 0.02%     

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 68 

                     
  OFF-CENTER load cells series PTC                             

  ATEX         

  Download data sheet

  Kg   50 - 75 - 100 - 150 ( for platforms 400 x 400 mm )

Click on the picture to enlarge

  - Stainless steel construction

  - Combined error < +/- 0.02%     

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 67 

                     
 OFF-CENTER load cells series AP        

  ATEX           

  Download data sheet

  Kg   50 - 150 - 300 ( for platforms 500 x 600 mm )  

Click on the picture to enlarge

  - Alloy aluminum construction

  - Combined error < +/- 0.03%       

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 65   

                     
 OFF-CENTER load cells series APL          

  OIML R60        ATEX         

  Download data sheet

  Kg   50 - 150 - 200 - 300 - 500 ( for platforms 600 x 600 mm )  

Click on the picture to enlarge

  - Alloy aluminum construction

  - Combined error < +/- 0.02%       

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 65   

                     
 OFF-CENTER load cells series AM        

  OIML R60       ATEX           

  Download data sheet  

  Kg   60 - 100 - 150 - 200 - 300 ( per piattaforme 400 x 400 mm )  

Click on the picture to enlarge

  - Alloy aluminum construction

  - Combined error < +/- 0.02%       

  - Sensitivity 2 mV/V +/- 5%

  - Protection class IP 65   

                     
  OFF-CENTER load cells series PE                          

  OIML R60       ATEX          

  Download data sheet

  Kg   75 - 150 - 300 - 500 ( for platforms 600 x 600 mm )

Click on the picture to enlarge

  - Special steel construction

  - Combined error < +/- 0.02%     

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 67 

                     
  OFF-CENTER load cells series PEC                              

  ATEX          

  Download data sheet

  Kg   75 - 150 - 300 - 500 ( for platforms 600 x 600 mm )

Click on the picture to enlarge

  - Stainless steel construction

  - Combined error < +/- 0.02%     

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 67 

                     
  OFF-CENTER load cells series PEI                              

  OIML R60       ATEX                

  Download data sheet

  Kg   75 - 100 - 150 - 300 - 500 ( for platforms 600 x 600 mm )

Click on the picture to enlarge

  - Stainless steel construction

  - Combined error < +/- 0.02%     

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 68 

                     
  OFF-CENTER load cells serie AR        

  ATEX           

  Download data sheet

  Kg   500 - 1000 ( for platforms 800 x 800 mm )  

Click on the picture to enlarge

  - Alloy aluminum construction

  - Combined error < +/- 0.02%       

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 65   

                     
  OFF-CENTER load cells series PL                           

  OIML R60       ATEX         

  Download data sheet

  Kg   500 - 1000 - 1800  ( for platforms 800 x 800 mm )

Click on the picture to enlarge

  - Special steel construction

  - Combined error < +/- 0.025%

  - Sensitivity 2 mV/V +/-10%      

  - Protection class IP 67

    
  OFF-CENTER load cells serie AT    

  ATEX           

  Download data sheet

  Kg   1000 - 2000 ( for platforms 1200 x 1200 mm )  

Click on the picture to enlarge

  - Alloy aluminum construction

  - Combined error < +/- 0.03%       

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 65   

    
  OFF-CENTER load cells serie ATL    

  OIML R60       ATEX           

  Download data sheet

  Kg   1000 - 2000 ( for platforms 1200 x 1200 mm )  

Click on the picture to enlarge

  - Alloy aluminum construction

  - Combined error < +/- 0.02%       

  - Sensitivity 2 mV/V +/-10%

  - Protection class IP 65   

    
  BENDING BEAM load cells series FCK                          

  Download data sheet    Mounting accessories

  Kg   5 - 10

Click on the picture to enlarge

  - Stainless steel construction

  - Combined error < +/- 0.02%    

  - Sensitivity 2 mV/V +/- 0.1%  

  - Protection class IP 68    

                     
  BENDING BEAM load cells series FCOL                          

  OIML R60       ATEX           

  Download data sheet    Mounting accessories

  Kg   20 - 50 - 100 - 200 - 350 - 500

Click on the picture to enlarge

  - Stainless steel 17-4 ph construction

  - Combined error < +/- 0.02%    

  - Sensitivity 2 mV/V +/- 1%  

  - Protection class IP 68    

                     
  BENDING BEAM load cells series FCAL                             

  OIML R60       ATEX           

  Download data sheet   Mounting accessories

  Kg   30 - 50 - 75 - 150 - 300

Click on the picture to enlarge

  - Stainless steel construction

  - Combined error < +/- 0.017%    

  - Sensitivity 2 mV/V +/- 0.1%  

  - Protection class IP 68 

                     
  BENDING & SHEAR BEAM load cells series FCAX                           

  ATEX         

  Download data sheet   Mounting accessories

  bending beam  Kg  75 - 150 - 300 - 500
  shear beam  Kg  750 - 1000

Click on the picture to enlarge

  - Stainless steel construction

  - Combined error <+/-0.02%

  - Sensitivity 2mV/V +/- 0.1% 

  - Protection class IP 68

    
  BENDING & SHEAR BEAM load cells series FCA                           

  OIML R60       ATEX             

  Download data sheet   Mounting accessories

  bending beam  Kg  500
  shear beam  Kg  750 - 1000

Click on the picture to enlarge

  - Special steel construction (stainless steel bellows)

  - Combined error <+/-0.02%

  - Sensitivity 2mV/V +/- 0.1% 

  - Protection class IP 67

    
  BENDING BEAM load cells series FTO                         <